| Functionality Description |
MITPC100 |
| TECHNICAL CONTROL PERFORMANCE |
| Control mode |
SVC, V/F |
| Motor type |
Asynchronous motro |
| Speed control accuracy |
±0.5% (SVC) |
| Starting torque |
0.25Hz/150% (SVC) |
| Torque boost |
Automatic torque boost; manual torque boost 0.1%~30.0% |
| OPERATIONAL CONTROL PERFORMANCE |
| Frequency command |
Digital setting, analog voltage setting, analog current setting, pulse setting, serial port setting, keyboard potentiometer setting. Can be switched in many ways. |
| Auxiliary frequency command |
Eleven kinds of auxiliary frequency commands, which can flexibly realize auxiliary frequency fine-tuning and frequency synthesis. |
| Operation command |
Operation command operator panel setting / Control terminal setting / Serial communication port setting / Can be switched in a variety of ways. |
| Automatic voltage adjustment function |
When the grid voltage changes, it can automatically keep the output voltage constant. |
| Speed tracking restart function |
Achieve shock-free and smooth start to the rotating motor |
| EFFICIENCY |
| MPPT tracking efficiency |
99.5%max (PV mode) |
| PROTECTION |
| Loss phase protection |
Input / output loss phase protection |
| Instantaneous overcurrent protection |
Stop at ≥250% of rated output current |
| Over-voltage protection |
Stop at ≥800V of main circuit DC voltage |
| Low-voltage protection |
The main circuit DC voltage will stop when undervoltage (different depending on the model) |
| Over-temperature protection |
Protection will be triggered when the inverter bridge over-temperature |
| Overload protection |
Over-load ≥150% 60s,inverter will shutd own |
| Over current protection |
If rated current over 2.5 times, inverter will shutdown for protection |
| Brake protection |
Braking unit overload protection, braking resistor short circuit protection |
| Short circuit protection |
Output phase short circuit protection |
| CONTROL SINGLE |
| Communication interface |
RS-485 interface |
| Input terminal X |
8 X terminals, more than fifty kinds of input function options. The X8 terminal supports high-speed pulse signal input. |
| Output terminal |
1 high-speed pulse output terminal (open-collector type is optional),
supports 0~100kHz square wave signal output; 2 AO terminals; 2 relay output terminals. |
| Control voltage source output |
DC24V, 100mA |
| Analog signal input |
AI1: 0V~+10V; AI2: 0~+10V / 0~20mA, the main board dial switch selection. AI3: -10V~+10V; |
| Analog signal output |
2 ways, 0~+10V / 0~20mA output programmable, selected by the main board dial switch. |
| Open-collector output |
2 ways, multiple operating states are optional; the maximum output current is 50mA. |
| Programmable rellay output |
2 ways, multiple states are available; contact capacity: 250VAC/3A or 30VDC/1A. |
| DISPLAY |
| Five-digit display |
31 state parameters such as setting frequency, output frequency, output voltage, output current, motor speed, output torque, switch value terminal, etc., programming menu parameters and
25 fault codes, etc. |
| Indicator light (LED) |
Parameter unit, setting direction, RUN/STOP status, control mode |
| ENVIROMENT |
| Use occasions |
The room is free from direct sunlight, dust, corrosive gas, combustible gas, oil mist, water vapor, dripping water or salt, etc |
| Altitude |
1000 meters below sea level (When the altitude exceeds 1000m, derate at a rate of 1% per 100m height) |
| Ambient temperature |
-10℃ ~+40℃ , it is not recommended to tun above 50℃
(when the ambient temperature exceeds 40℃ , derate at a rate of 3% per 1℃ derating) |
| Humidity |
5%~95%RH, no condensation |
| Vibration |
Less than 5.9m/s2 (0.6g) |
| Storage temperature |
-20℃ ~ +60℃ , air temperature change is less than 1℃ /min |
| Protection class |
IP20 |
| STRUCTURE |
| Cooling method |
Air cooling |
| Installation type |
Wall-mounted |